Evs XTAccess Version 1.10 - July 2009 User Manual Instrukcja Użytkownika Strona 87

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 86
Issue 1.10.D XTAccess Version 1.10
User’s Manual
Author: Serge Comes - EVS Broadcast Equipment – July 2009
86
o %BDATE -> Backup Date
o %BYEAR -> Backup Year
o %BMONTH -> Backup Month
o %BDAY -> Backup Day
o %VCODEC -> Video Codec
18.4.5 REGISTRY SETTINGS
HKEY_LOCAL_MACHINE\SOFTWARE\EVS Broadcast Equipment\Common
\FileWriter NoBuffering: Specific setting to transfer a file without any
buffering. Recommended for writing on a MacOS workstation via network
(SMB). (default value = 0)
HKEY_CURRENT_USER\Software\EVS Broadcast Equipment\XTAccess\Max
Transfer Rate: Maximum transfer rate (Bytes/second) for the total amount of
backup jobs (all together).
HKEY_CURRENT_USER\Software\EVS Broadcast Equipment\XTAccess\Safe
Train Backup: protection to avoid reaching the head of a train during backup of
train:
o 0: Active
o 1: Not Active
18.5 MISCELLANEOUS
18.5.1 BACKUP/UPDATE OF TRAINS AND LOAD BALANCING
It is not recommended to perform load balancing between several XML Scan
folders when requesting backup of trains.
We recommend dedicating specific XTAccess for your Backup of train. For
example one XTAccess for two backups of train. Like this, you are sure that
your backups of train are done directly and quickly.
18.5.2 MAX XML JOBS PER SCAN SETTING
It is recommended to set the Max XML Job per Scan registry setting with a very
high value (e.g. 100) when performing backup of trains jobs.
In that way, all incoming jobs will be loaded by XTAccess (in the “Scheduled
folder). In case of an update XML job, this request will be automatically loaded
by XTAccess and parsed to check which job is concerned. The backup of trains
will be loaded even if it is still in a scheduled or processing mode.