EVS XT-3 Instrukcja Użytkownika Strona 89

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 105
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 88
6.2.5. CODConnectivity in SLSM 2Ph Single Link
3G-SDI
This section describes the connector assignments and layout for the SLSM 2-phase
cameras in Single Link 3G-SDI mode.
Connector Assignments
Con-
nector
SLSM 2-Phase 3G Mode
Connector
label
J1 N/A CHAR SD
J2 SDI program output
(SD, down-converted)
Not wired to the
backplane.
Used for
onboard
multiviewer
input
J3 SDI program output of phase 1
(HD/SD)
OUT B
J4 SDI monitoring output in SLSM
(HD/SD)
CHAR OUT
SD/HD
J5 Not installed IN B
J6 HD program output of phase 1
(identical to J7)
OUT
J7 HD program output of phase 1
(identical to J6)
OUT
J8 3G-SDI SLSM 2Ph input
(3G)
IN
J9 Alternate 3G-SDI SLSM 2Ph input
(3G, for hardware loop)
Not wired to the
backplane.
Used for loop in.
Note
The loops of the input signal are not genlocked.