The following screenshot presents the page 1 of the Channels tab, where the port settings
are available in the server-based application, and highlights the port settings field group:
RS422 #1 - #6
Description Specifies what type of device/controller is connected to each
RS422 port of the EVS server.
Values The following values can be available if the required license
codes are active:
• 'EVS Remote' for LSM Remote Panel (code between 103
and 109).
• 'EVS Remote' for XSense Remote Panel (code between
103 and 109 or code 96)
• 'EVS IPDP' (code 120 or 121)
• 'Sony BVW75' (code 118)
• 'XtenDD35' (code 118)
• 'Odetics' and 'Odetics FK' (code 119)
• 'VDCP' and 'VDCP FK' (code 119)
• 'EVS AVSP' (code 120 or 121)
• 'Edit Rec' (code 122)
• 'Linx' (code 123)
• 'Touch screen'
Default On port #1 (only): IPDP
Rules The following rules are applicable for assigning the following
controlling devices to RS422 ports:
• In all base configurations that rely on an EVS Remote
Controller, the 'EVS Remote' shall always to be assigned
to the first allocated RS422 port.
• A touch screen can only be assigned to port 6.
XT3 Server-Version 11.00-Configuration Manual
3. Multicam Configuration 74